COMMERCIAL STEAM GENERATORS SPECIFICATION CHART

(CU1000 Shown Above)

To determine the correct CU Steambath Generator Model:
Multiply length x width x height of the steam room.
Compare your total room volume to the Specification Chart to select the correct model.


Example 1:

A steam room 8' x 10' x 8' H = 640 cu. ft. (volume).
Select the next size generator model which exceeds the calculated room volume. In this example, specify Model CU750 with one DIGITAL 1 Control Package

Example 2:

2 steam rooms each 6' x 10' x 7' H x 2 = 840 cu. ft. (volume).
In this example specify Model CU1000 with 2 (two) DIGITAL 1 Control Packages



MODEL #
Total Room Volume
PHKWShip Wt
LengthWidthHeight
CU360 Up to 360
1 or 3
9
200 3626
43
CU500 361-500 1 or 3
12 20036
2643
CU750 501-7501 or 3
18 200 36 26 43
CU1000 751-1000 1 or 3 24 200 36 26 43
CU1250 1001-1250 3 30 200 36 26 43
CU1400 1251-1400 3 36 200 36 26 43
CU2000 1401-2000 3 48 300 37 31 52
CU2500 2001-2500 3 60 300 36 26 43
CU3000 2501-3000 3 72 320 3626 43
CU4500 3001-4500 3 108 525 47 37 74
Note 1

Certain additional factors affect the correct sizing of the Steambath Generator. Construction materials such as glass, glass block, natural marble or other stones, as well as steam piping longer than 50 feet, exterior walls and outside windows will all require a larger Steambath Generator.


For more detailed product information, contact customer service, or click here to view Commercial Installation, Operation and Maintenance Manuals

Note 2

The guidelines for selecting the steam bath generator are a recommendation only. Because of variables in construction, these sizing instructions and specifications should be considered as guidelines only. Mr. Steam will review the model selected provided we receive complete information, including working drawings, specifications and pertinent electrical and construction details.

Important: When specifying a CU Commercial Steam bath Generator, the following is strongly recommended for best performance and user satisfaction:

  1. One (1) CU steambath generator should service no more than two (2) steamrooms, each relatively similar in size and construction.
  2. If two (2) steamrooms are serviced by one (1) CU generator, the combined resultant room volume of the two (2) rooms should not exceed 1000 cubic feet (28.3 cubic meters).
  3. Each room must be operated with the appropriate F1 PLUS® temperature control system, inclusive of the room operating temperature control and the high-limit temperature control.
  4. In all installations, the purchaser and/or owner/operator must consult with a designer, architect, and or consultant to assure the proper specification of the steambath generator and required and optional operating equipment.
Note 3

The available CU Club Package includes the AutoFlush® System and the AromaFlo® Essential Oil Injection System.